Each downloadable file
is a self-extracting zip file containing a "Read Me" file,
WinWedge configuration files, and a sample Excel spreadsheet. If
you are unsure which version of WinWedge you have open WinWedge
and click on HELP > About.
Also listed here are
(what we believe to be) the standard settings for each device. This
information is based upon data gathered from the customers and/or
manufactures of these devices. We cannot guarantee that it is accurate
or up to date. When in doubt consult your device's user manual or
contact the manufacturer. The sample spreadsheets and configurations
are based on these settings so you may need to modify them.
|
3D Instruments:
Star Series Pressure
Calibrator
- Std Settings: 2400, N, 8, 1, None
- Transmit Data: N/A
DTG-6000 Pressure
Gauge
- Std Settings:
9600, N, 8, 1, None
- Transmit Data: N/A
|
|
|
Bowers Metrology:
All electronic measuring tools, including Bore gauges and
Hole gauges
- Std Settings: 4800, E, 7, 2, None
- Transmit Data: Toggle DTR Line
|
|
|
Denver:
Accumet pH meter
- Std Settings: 4800, N, 8, 1, Hardware
- Transmit Data: N/A
Moisture Analyzer
- Std Settings: 4800, N, 8, 1, None
- Transmit Data: N/A
Balance
- Std Settings: 300, N, 8, 1, None
- Transmit Data: P<CR>
|
|
|
DGH Corp:
Most DGH modules
- Std Settings: 300, N, 8, 1, None
- Transmit Data: $1RD<CR>
|
|
|
Fowler:
Sylvac Calipers, gauges, and other measuring instruments
- Std Settings: 4800, E, 7, 1, None
- Transmit Data: Toggle DTR Line
|
|
|
Imada:
Digital Force Gauge
- Std Settings: 2400, N, 8, 1, None
- Transmit Data: D<CR>
- Peak Mode: P<CR>
- Tare: Z<CR>
|
|
|
Mark-10:
Digital Force Gauge
- Std Settings: 9600, N, 8, 1, None
- Transmit Data: ?<CR>
|
|
|
Mettler:
pH meter
- Std Settings: 2400, E, 7, 1, None
- Transmit Data: R
Balance
- Std Settings: 2400, E, 7, 1, None
- Transmit Data: S<CR><LF>
- Alternate Transmit cmd: W<CR><LF>
Titrator
- Std Settings: 2400, N, 8, 1, Xon/Xoff
- Transmit Data: N/A
|
|
|
Ohaus:
Voyager density balance
- Std Settings: 2400 or 9600, N, 8, 1, None
- Transmit Data: P<CR><LF>
|
|
|
Orion:
pH meter
- Std Settings: 1200, N, 8, 1, None
- Transmit Data: pr<CR>
|
|
|
Rice Lake Weighing systems:
IQ Plus 510/710
IQ Plus 590-DC
IQ Plus 355
IQ Plus 390-DC
- Std Settings: 9600, N, 8, 1, None
- Transmit Data: KPRINT<CR>
|
|
|
Sartorius:
Balance
- Std Settings: 1200, Odd, 7, 1, None
- Transmit Data: ESC (ASCII 27) P
Note: Has unusual pin-outs so
cannot use a standard serial cable
|
|

Useful information about other common
devices
|