Each downloadable
file is a self-extracting zip file containing a "Read
Me" file, WinWedge configuration files, and a sample
Excel spreadsheet. If you are unsure which version of WinWedge
you have open WinWedge and click on HELP > About.
Also listed here
are (what we believe to be) the standard settings for each
device. This information is based upon data gathered from
the customers and/or manufactures of these devices. We
cannot guarantee that it is accurate or up to date. When
in doubt consult your device's user manual or contact the
manufacturer. The sample spreadsheets and configurations
are based on these settings so you may need to modify them.
|
3D Instruments:
Star Series
Pressure Calibrator
- Std Settings: 2400, N, 8, 1, None
- Transmit Data: N/A
DTG-6000
Pressure Gauge
- Std
Settings: 9600, N, 8, 1, None
- Transmit Data: N/A
|
|
|
Bowers Metrology:
All electronic measuring tools, including Bore gauges and Hole gauges
- Std Settings: 4800, E, 7, 2, None
- Transmit Data: Toggle DTR Line
|
|
|
Denver:
Accumet pH meter
- Std Settings: 4800, N, 8, 1, Hardware
- Transmit Data: N/A
Moisture Analyzer
- Std Settings: 4800, N, 8, 1, None
- Transmit Data: N/A
Balance
- Std Settings: 300, N, 8, 1, None
- Transmit Data: P<CR>
|
|
|
DGH Corp:
Most DGH modules
- Std Settings: 300, N, 8, 1, None
- Transmit Data: $1RD<CR>
|
|
|
Fowler:
Sylvac Calipers, gauges, and other measuring instruments
- Std Settings: 4800, E, 7, 1, None
- Transmit Data: Toggle DTR Line
|
|
|
Imada:
Digital Force Gauge
- Std Settings: 2400, N, 8, 1, None
- Transmit Data: D<CR>
- Peak Mode: P<CR>
- Tare: Z<CR>
|
|
|
Mark-10:
Digital Force Gauge
- Std Settings: 9600, N, 8, 1, None
- Transmit Data: ?<CR>
|
|
|
Mettler:
pH meter
- Std Settings: 2400, E, 7, 1, None
- Transmit Data: R
Balance
- Std Settings: 2400, E, 7, 1, None
- Transmit Data: S<CR><LF>
- Alternate Transmit cmd: W<CR><LF>
Titrator
- Std Settings: 2400, N, 8, 1, Xon/Xoff
- Transmit Data: N/A
|
|
|
Ohaus:
Voyager density balance
- Std Settings: 2400 or 9600, N, 8, 1, None
- Transmit Data: P<CR><LF>
|
|
|
Orion:
pH meter
- Std Settings: 1200, N, 8, 1, None
- Transmit Data: pr<CR>
|
|
|
Rice Lake Weighing systems:
IQ Plus 510/710
IQ Plus 590-DC
IQ Plus 355
IQ Plus 390-DC
- Std Settings: 9600, N, 8, 1, None
- Transmit Data: KPRINT<CR>
|
|
|
Sartorius:
Balance
- Std Settings: 1200, Odd, 7, 1, None
- Transmit Data: ESC (ASCII 27) P
Note: Has unusual pin-outs so
cannot use a standard serial cable
|
|
Related Links
Useful information about other common
devices |