When thinking of something you don’t want to break or tear when stretched, rubber bands, bungee cords, fishing lines, cables, your pants, maybe even muscles come to mind. But definitely not your skin. The elasticity and strength of our skin is something we all take for granted. But not Bio Med Sciences, Inc., Bethlehem, PA, who since 1987, has produced a patented “synthetic skin” formulation which combines the properties of silicone and polytetrafluoroethylene (commonly known as “teflon”) and is used for biomedical applications.
Silon products
In producing their formulation, Bio Med developed a simple system that increases productivity and accuracy during the quality control testing of their formulation. The elasticity and strength of the formulation, named Silon-IPN, is critical, since Bio Med has developed it for a wide variety of commercial applications including the healing and treatment of wounds and burns. These commercial applications comprise the family of Silon-IPN products, which include (i) Silon-TSR Temporary Skin Replacement, a dressing substance for promoting moist wound healing and pain reduction for patients; (ii) Silon-SES Silicone Elastomer Sheeting , a soft and durable material used with pressure garments worn during the care of wounds to promote healing and patient comfort and reduce keloids (scar tissue) and hypertrophic scaring; (iii) Silon-STS Silicone Thermoplastic Splinting, a material which combines a therapeutic surface of silicone with a moldable orthotic material to manage burn scars and scar treatment.
Automating quality control measurements
Initially, Bio Med performed quality control strength and elasticity testing manually. The manual pendulum-type measuring system, which involved manually transcribing force load and elongation measurements on paper and then typing them into a Microsoft Access database, proved to be time consuming and error-prone. Mark Dillon, a materials engineer and the president of Bio Med, designed an automated quality control testing system to ensure quality and consistency in their manufacturing. In designing the system, Dillon sought measuring tools that would allow automation and a software program to serve as a communication interface between his measuring instruments and his Microsoft Access database. Dillon preferred to maintain his data in Access since he had already developed an Access-based reporting system.
To determine the strength characteristics of the manufactured Silon materials, the breaking point force and elongation of the materials are measured as samples are pulled on a tension tester. To accomplish this, the samples are placed on a tension and compression testing machine (manufactured by Chatillon, Greensboro, NC, model number TCD200) with a force gage (manufactured by Mark-10 Corporation, Hicksville, NY, model BG-10) mounted on it. The samples are then stretched to the breaking point. The breaking point measurements, including the force applied and elongation, are then transmitted automatically to a PC running a Microsoft Access. These maximum tension strength values are then compared to quality control values in the Access database.
The automation of the quality control testing is possible since both the tension and compression testing machine and the force gage have RS232 output. Both devices are connected directly to two different serial ports on the PC. The readings are filtered and sent to the Access database using the WinWedge Standard version data acquisition software from TAL Technologies, Philadelphia, PA (800-722-6004, http://www.www.taltech.com). WinWedge serves as the communication interface between the two measuring devices and the Access database. The Wedge communicates with each device independently and directs the data to the appropriate fields in the Access database.
WinWedge benefits
Dillon found that by automating the quality control strength testing, the process takes half as much time as the manual process. Dillon noted, “The data entry used to take as much time as the actual testing and analysis”. Dillon added, “WinWedge has saved us a lot of time and improved our accuracy to 100%.”
Additionally, Dillon recently began developing strength profiles by graphing the force load data continuously over time in Microsoft Excel. The elongation can also be calculated since the samples are pulled at a constant rate (distance=rate x time).
For more information on the innovation taking place at Bio Med Sciences, please visit their web site at http://www.silon.com.